avnerus [14 Gently test inflation with a syringe]
Line 4: Line 4:
  
 ===== - Choose your mold and figure out required silicone quantities ​  ===== ===== - Choose your mold and figure out required silicone quantities ​  =====
-Refer to the [[soft-robotics:​molds|molds]] page for a list of known molds and quantities. +  * Refer to the [[soft-robotics:​molds|molds]] page for a list of known molds and quantities. 
-Leave at least 20gr for gluing. +  * Check if your mold is a [[soft-robotics:​fast-pneunet|Fast Pneunet]] or [[soft-robotics:​slow-pneunet|Slow Pneunet]] to figure out which silicone is supports. 
-Get both body and base layers ready for pouring before you start mixing.+  * Leave at least 20gr for gluing. 
 +  ​* ​Get both body and base layers ready for pouring before you start mixing.
  
 +{{:​soft-robotics:​03.png?​nolink&​400|}}
 ===== - Apply coating to the molds   ===== ===== - Apply coating to the molds   =====
 Coating the molds in Vaseline would later help removing the cured silicone from the mold. Coating the molds in Vaseline would later help removing the cured silicone from the mold.
 +
 +{{:​soft-robotics:​02.png?​nolink&​400|}}
  
 ===== - Prepare any extra strain limiting materials ​  ===== ===== - Prepare any extra strain limiting materials ​  =====
Line 17: Line 21:
 Refer to the [[soft-robotics:​silicones|silicones]] page to figure out the ratio working time of your silicone. If you don't have a centrifugal mixer, use wooden mixing sticks. Mix thoroughly for 3 minutes. Weak mixing may result in curing failure. Refer to the [[soft-robotics:​silicones|silicones]] page to figure out the ratio working time of your silicone. If you don't have a centrifugal mixer, use wooden mixing sticks. Mix thoroughly for 3 minutes. Weak mixing may result in curing failure.
  
-===== - Place the mixed silicone cup in the vacuum chamber ​for ~5 minuets ​  =====+{{:​soft-robotics:​04.png?​nolink&​400|}} 
 +===== - Place the mixed silicone cup in the vacuum chamber =====
 5 minuets should be enough to get rid of initial bubbles. 5 minuets should be enough to get rid of initial bubbles.
  
-===== Pour the silicone into the molds (Base layer only half way through) ​  ​===== +{{:soft-robotics:05.png?​nolink&​400|}}
-Pour gently and slowly. Allow the silicone to spread evenly and then pour more layers. For the base layer, pour only half of the silicone.+
  
-===== - Place the molds in the vacuum chamber ​for ~5 minuets and pop out bubbles ​=====+===== - Pour the silicone into the molds ===== 
 +Pour gently and slowly. Allow the silicone to spread evenly and then pour more layers. For the base layer, pour only half of the silicone, as you will later add the strain limiting layer. 
 + 
 +{{:​soft-robotics:​06.png?​nolink&​400|}} 
 +===== - Place the molds in the vacuum chamber =====
 After 5 minutes lots of bubbles will rise to the surface. Pop them out with a pipette tip or other plastic instrument. After 5 minutes lots of bubbles will rise to the surface. Pop them out with a pipette tip or other plastic instrument.
  
 +{{:​soft-robotics:​08.png?​nolink&​400|}}
 ===== - Place strain limiting material on the base layer ===== ===== - Place strain limiting material on the base layer =====
 Refer to the [[soft-robotics:​strain-limiting|strain limiting]] page for more info. Refer to the [[soft-robotics:​strain-limiting|strain limiting]] page for more info.
 +
 +{{:​soft-robotics:​07.png?​nolink&​400|}}
  
 ===== - Place the molds in the oven at 65C ===== ===== - Place the molds in the oven at 65C =====
Line 35: Line 46:
   - **Check that the fill height didn’t drop more than 2mm** - If it did, fill in extra silicone (Make a new cup, don't use an old one) and put back in he oven.   - **Check that the fill height didn’t drop more than 2mm** - If it did, fill in extra silicone (Make a new cup, don't use an old one) and put back in he oven.
  
 +{{:​soft-robotics:​09.png?​nolink&​400|}}
 +
 +===== - Remove the cured silicone from the molds =====
 +Each [[soft-robotics:​molds|mold]] may have different methods for removing. The silicone is quite strong so it's OK to use a flathead screwdiver. We have also used a metal knitting needle to cut through the seams of the mold. 
 +
 +Notice that if you overfilled your mold, you may have silicone attached above the edges of the mold. Use a utility knife to cut the excess attachment.
 +
 +{{:​soft-robotics:​10.png?​nolink&​400|}}
 +
 +===== - Make new silicone for the base layer + gluing =====
 +Do not reuse old silicone as it may have already been cured.
 +
 +{{:​soft-robotics:​04.png?​nolink&​400|}}
 +===== - Glue the body layer to the base layer ====
 +  - First put the base silicone back into its mold.
 +  - Fill up new silicone all the way up to the base mold.
 +Refer to the [[http://​softroboticstoolkit.com|soft robotics toolkit]] guide:
 +<​code>​
 +Place the top piece of the actuator on the base so that it settles into the uncured Silicone, ​
 +and press down gently. If you press too hard, the central channel of the actuator ​
 +may become blocked. Make sure to press down around the edges as well to ensure a good seal.
 +</​code>​
 +
 +{{:​soft-robotics:​13.png?​nolink&​400|}}
 +===== - Pierce a hole in the actuator and insert the tube ====
 +Use the metal knitting needle to pierce the hole and gently attach the tube.
 +Refer to the page of your [[soft-robotics:​molds|mold]] for specific instructions on where and how to pierce the hole.
 +
 +{{:​soft-robotics:​molds:​14.png?​nolink&​400|}}
 +===== - Gently test inflation with a syringe ====
 +**Do not inflate too much!** ​ - If the inflation works properly, let the actuator rest and cure until the next day. Two main issues may be revealed:
 +  - **The air channel is blocked** - If the actuator inflates only half way without any air running out, the air channel is blocked. use the knitting needle to gently pierce through the air channel until the block is removed.
 +  - **There is a hole** - If air is running out of the actuator, immerse it in water while inflating to figure out where there is a hole. Use more silicone or silicone glue to patch the hole and try again.
  
 +{{:​soft-robotics:​17.png?​nolink&​400|}}
    
  
soft-robotics/general-recipe.1492161233.txt.gz · Last modified: 2017/04/14 09:13 by avnerus